Standards
Applicable Standards
(1)Except as provided in Sentence (2) and elsewhere in this Part, materials and components, and their installation, shall conform to the requirements of the applicable standards in Table 5.9.1.1. where those materials or components are
- (a) incorporated into environmental separators or assemblies exposed to the exterior, and
- (b) installed to fulfill the requirements of this Part.
(2)The requirements for flame-spread ratings contained in thermal insulation standards shall be applied only as required in Part 3.
| Issuing Agency | Document Number | Title of Document |
|---|---|---|
| ANSI | A135.6 | Engineered Wood Siding |
| ASME | B18.6.1 | Wood Screws (Inch Series) |
| ASTM | A123 / A123M | Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products |
| ASTM | A153 / A153M | Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware |
| ASTM | A653 / A653M | Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process |
| ASTM | C4 | Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile |
| ASTM | C73 | Standard Specification for Calcium Silicate Brick (Sand-Lime Brick) |
| ASTM | C126 | Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units |
| ASTM | C212 | Standard Specification for Structural Clay Facing Tile |
| ASTM | C412M | Standard Specification for Concrete Drain Tile |
| ASTM | C444M | Standard Specification for Perforated Concrete Pipe |
| ASTM | C553 | Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications |
| ASTM | C612 | Standard Specification for Mineral Fiber Block and Board Thermal Insulation |
| ASTM | C700 | Standard Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated |
| ASTM | C728 | Standard Specification for Mineral Wool Roof Insulation Board |
| ASTM | C834 | Standard Specification for Latex Sealants |
| ASTM | C840 | Standard Specification for Application and Finishing of Gypsum Board |
| ASTM | C920 | Standard Specification for Elastomeric Joint Sealants |
| ASTM | C1104 | Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings |
| ASTM | C1177 / C1177M | Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing |
| ASTM | C1178 / C1178M | Standard Specification for Coated Glass Mat Water-Resistant Gypsum Backing Panel |
| ASTM | C1184 | Standard Specification for Structural Silicone Sealants |
| ASTM | C1280 | Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing |
| ASTM | C1311 | Standard Specification for Solvent Release Sealants |
| ASTM | C1330 | Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-Applied Sealants |
| ASTM | C1396 / C1396M | Standard Specification for Gypsum Board |
| ASTM | C1658 / C1658M | Standard Specification for Glass Mat Gypsum Panels |
| ASTM | D1227 / D1227M | Standard Specification for Emulsified Asphalt Used as a Protective Coating for Roofing |
| ASTM | D2178 / D2178M | Standard Specification for Asphalt Glass Felt Used in Roofing and Waterproofing |
| ASTM | D3019 / D3019M | Standard Specification for Lap Cement Used with Asphalt Roll Roofing, Non-Fibered, and Fibered |
| ASTM | D4479 / D4479M | Standard Specification for Asphalt Roof Coatings – Asbestos-Free |
| ASTM | D4637 / D4637M | Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane |
| ASTM | D4811 / D4811M | Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing |
| ASTM | D6878 / D6878M | Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing |
| ASTM | E2190 | Standard Specification for Insulating Glass Unit Performance and Evaluation |
| BNQ | BNQ 3624-115 | Polyethylene (PE) Pipe and Fittings for Soil and Foundation Drainage |
| CGSB | CAN/CGSB-11.3-M | Hardboard |
| CGSB | CAN/CGSB-12.1 | Safety Glazing |
| CGSB | CAN/CGSB-12.2-M | Flat, Clear Sheet Glass |
| CGSB | CAN/CGSB-12.3-M | Flat, Clear Float Glass |
| CGSB | CAN/CGSB-12.4-M | Heat Absorbing Glass |
| CGSB | CAN/CGSB-12.8 | Insulating glass units |
| CGSB | CAN/CGSB-12.9-M | Spandrel glass |
| CGSB | 37-GP-9Ma | Primer, Asphalt, Unfilled, for Asphalt Roofing, Dampproofing and Waterproofing |
| CGSB | CAN/CGSB-37.50-M | Hot-Applied, Rubberized Asphalt for Roofing and Waterproofing |
| CGSB | CAN/CGSB-37.54 | Polyvinyl Chloride Roofing and Waterproofing Membrane |
| CGSB | CAN/CGSB-37.58-M | Membrane, Elastomeric, Cold-Applied Liquid, for Non-Exposed Use in Roofing and Waterproofing |
| CGSB | CAN/CGSB-51.32-M | Sheathing, Membrane, Breather Type |
| CGSB | CAN/CGSB-51.33-M | Vapour Barrier Sheet, Excluding Polyethylene, for Use in Building Construction |
| CGSB | CAN/CGSB-51.34-M | Vapour Barrier, Polyethylene Sheet for Use in Building Construction |
| CGSB | CAN/CGSB-93.1-M | Sheet, Aluminum Alloy, Prefinished, Residential |
| CGSB | CAN/CGSB-93.2-M | Prefinished Aluminum Siding, Soffits, and Fascia, for Residential Use |
| CSA | A23.1 | Concrete materials and methods of concrete construction |
| CSA | CAN/CSA-A82 | Fired masonry brick made from clay or shale |
| CSA | CAN3-A93-M | Natural Airflow Ventilators for Buildings |
| CSA | CAN/CSA-A123.2 | Asphalt-Coated Roofing Sheets |
| CSA | A123.3 | Asphalt Saturated Organic Roofing Felt |
| CSA | CAN/CSA-A123.4 | Asphalt for Constructing Built-Up Roof Coverings and Waterproofing Systems |
| CSA | A123.5 | Asphalt shingles made from glass felt and surfaced with mineral granules |
| CSA | CAN/CSA-A123.16 | Asphalt-coated glass-base sheets |
| CSA | A123.17 | Asphalt Glass Felt Used in Roofing and Waterproofing |
| CSA | A123.23 | Product specification for polymer-modified bitumen sheet, prefabricated and reinforced |
| CSA | A123.51 | Asphalt shingle application on roof slopes 1:6 and steeper |
| CSA | A165.1 | Concrete block masonry units |
| CSA | A165.2 | Concrete brick masonry units |
| CSA | A165.3 | Prefaced concrete masonry units |
| CSA | CAN/CSA-A179 | Mortar and Grout for Unit Masonry |
| CSA | CAN/CSA-A220 Series | Concrete Roof Tiles |
| CSA | CAN/CSA-A371 | Masonry Construction for Buildings |
| CSA | A3000 | Cementitious Materials for Use in Concrete |
| CSA | B182.1 | Plastic drain and sewer pipe and pipe fittings |
| CSA | G40.21 | Structural quality steel |
| CSA | CAN/CSA-G401 | Corrugated steel pipe products |
| CSA | CAN/CSA-O80 Series | Wood preservation |
| CSA | O118.1 | Western Red Cedar Shakes and Shingles |
| CSA | O118.2 | Eastern White Cedar Shingles |
| CSA | O121 | Douglas fir plywood |
| CSA | O141 | Softwood Lumber |
| CSA | O151 | Canadian softwood plywood |
| CSA | O325 | Poplar plywood |
| CSA | O325.0 | Construction sheathing |
| CSA | O437.0 | OSB and Waferboard |
| CSA | O86.1 | Durability in buildings |
| HPVA | ANSI/HPVA HP-1 | American National Standard for Hardwood and Decorative Plywood |
| ULC | CAN/ULC-S701.1 | Standard for Thermal Insulation, Polystyrene Boards |
| ULC | CAN/ULC-S702.1 | Standard for Mineral Fibre Thermal Insulation for Buildings, Part 1: Material Specification |
| ULC | CAN/ULC-S703 | Standard for Cellulose Fibre Insulation (CFI) for Buildings |
| ULC | CAN/ULC-S704.1 | Standard for Thermal Insulation, Polyurethane and Polyisocyanurate, Boards, Faced |
| ULC | CAN/ULC-S705.1 | Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Material Specification |
| ULC | CAN/ULC-S705.2 | Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Application |
| ULC | CAN/ULC-S706.1 | Standard for Wood Fibre Insulating Boards for Buildings |
| ULC | CAN/ULC-S710.1 | Standard for Bead-Applied One Component Polyurethane Air Sealant Foam, Part 1: Material Specification |
| ULC | CAN/ULC-S711.1 | Standard for Bead-Applied Two Component Polyurethane Air Sealant Foam, Part 1: Material Specification |
| ULC | CAN/ULC-S717.1 | Standard for Flat Wall Insulating Concrete Form (ICF) Units – Material Properties |
Windows, Doors and Skylights
(1)This Subsection applies to windows, doors and skylights, including their components, that separate
- (a) interior space from exterior space, or
- (b) environmentally dissimilar interior spaces.
(2)For the purpose of this Subsection, the term "skylight" refers to unit skylights, roof windows and tubular daylighting devices.
(3)Where a wired glass assembly is installed in a required fire separation, it need not conform to the requirements of this Subsection.
(1)Windows, doors and skylights shall conform to the requirements in
- (a) AAMA/WDMA/CSA 101/I.S.2/A440, "North American Fenestration Standard/Specification for windows, doors, and skylights" (Harmonized Standard), and
- (b) CSA A440S1, "Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration Standard/Specification for windows, doors, and skylights."
(2)Performance grades for windows, doors and skylights shall be selected according to the Canadian Supplement referenced in Clause (1)(b) so as to be appropriate for the conditions and geographic location in which the window, door or skylight will be installed.
(3)Windows, doors and skylights shall conform to the performance grades selected in Sentence (2) when tested in accordance with the Harmonized Standard referenced in Clause (1)(a).
(1)Windows, doors, skylights and their components shall be designed and constructed in accordance with
- (a) Article 5.1.4.1., Section 5.4. and Section 5.6., where they are not covered in the scope of the standards listed in Sentence 5.9.2.2.(1), or
- (b) Article 5.9.2.2., where they are covered in the scope of the standards listed in Sentence 5.9.2.2.(1).
(1)Windows, doors and skylights shall meet the heat transfer performance requirements stated in Section 5.3.
(2)Except as provided in Sentence (3), all metal-framed glazed assemblies separating interior conditioned space from interior unconditioned space or exterior space shall incorporate a thermal break to minimize condensation.
(3)Metal-framed glazed assemblies need not comply with Sentence (2) where these assemblies are
- (a) storm windows or doors, or
- (b) windows or doors that are required to have a fire-protection rating.
Other Fenestration Assemblies
(1)In this Subsection, "other fenestration assemblies" means curtain walls, window walls, storefronts and glazed architectural structures.
(1)Other fenestration assemblies and their components shall be designed and constructed in accordance with Article 5.1.4.1.
(1)Other fenestration assemblies and their components shall meet the heat transfer performance requirements stated in Section 5.3.
(2)Other fenestration assemblies using metal framing that separate interior conditioned space from interior unconditioned space or exterior space shall incorporate a thermal break to minimize condensation.
(1)Other fenestration assemblies and their components shall be designed and constructed in accordance with Section 5.4.
(2)Except as provided in Sentence (3), other fenestration assemblies and their components shall have an air leakage characteristic, measured at an air pressure difference of 75 Pa, when tested in accordance with ASTM E283, "Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen," that is not greater than
- (a) 0.2 L/(s×m²) for fixed portions, including any opaque portions, and
- (b) 1.5 L/(s×m²) for operable portions.
(3)The following systems need not comply with Sentence (2):
- (a) interior windows and interior doors that do not serve as environmental separators,
- (b) vehicular access doors (garage doors),
- (c) storm windows and storm doors,
- (d) commercial entrance systems,
- (e) revolving doors,
- (f) smoke and relief air vents,
- (g) site-built door systems, and
- (h) commercial steel doors.
(1)Other fenestration assemblies and their components shall be designed and constructed in accordance with Section 5.6.
(2)Except as provided in Sentence (4), other fenestration assemblies and their components not covered in Article 5.9.2.2. shall resist water penetration when tested in accordance with
- (a) ASTM E331, "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference," or
- (b) ASTM E547, "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference."
(3)Tests referred to in Sentence (2) shall be carried out at the driving rain wind pressure as calculated in accordance with CSA A440S1, "Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration Standard/Specification for windows, doors, and skylights."
(4)The following systems need not comply with Sentence (2):
- (a) interior windows and interior doors,
- (b) vehicular access doors (garage doors),
- (c) storm windows and storm doors,
- (d) commercial entrance systems,
- (e) revolving doors,
- (f) smoke and relief air vents,
- (g) site-built door systems, and
- (h) commercial steel doors.
Exterior Insulation Finish Systems
(1)Exterior insulation finish systems and their components shall comply with
- (a) Subsection 5.1.4. and Sections 5.3. to 5.6., and
- (b) CAN/ULC-S716.1, "Standard for Exterior Insulation and Finish Systems (EIFS) - Materials and Systems," where covered in the scope of that standard.